The dryer filter should be cleaned every year

The milk tank equipment should be managed by a dedicated person.. Check the action of the high and low pressure controller, whether the pressure indicating position has changed, and whether the internal components of the control tank are rusted or damaged. The direct cooling milk storage tank adopts fully automatic control, and the electric control box can be installed on the side or near end of the milk tank for easy automatic control. In case of the above-mentioned faults, the circuit will be automatically disconnected, an alarm will be issued, and the compressor will stop working. When operating, pay attention to the operation of the refrigeration system and keep a record of the operation.

The dryer filter should be cleaned every year, and the desiccant should be cleaned , Drying or exchange. The refrigeration system should be checked for leaks with halogen lamps once a month. Check whether the mixer is short of oil and whether the oil seal is intact. The compressor has high-pressure pressure fault protection and motor overload protection (high-pressure protection value is 2. Any machine needs maintenance during use, and the same is true for direct cooling milk tanks. If abnormal conditions are found, the maintenance should be stopped in time. 5. If leaks are found, further comprehensive inspections are required. Check whether the digital display temperature controller is sensitive.0MPa, low-pressure shutdown value is 0. The refrigeration plate of the direct cooling milk tank has high refrigeration efficiency.

When the refrigeration unit is out of use in winter, the water in beer brewhouse Supplies the water condenser coil should be drained to prevent the coil from freezing and cracking. The milk tank equipment is combined with the electrical control box to automatically control the temperature of the refrigeration system. Because the insulation layer is filled with rigid foam material with low thermal conductivity, it is light in weight and excellent in insulation performance. The two refrigeration plates are respectively controlled by two sets of refrigeration compressors, which can work independently or at the same time to ensure that the milk is cooled quickly and uniformly without icing. You must check at this time After troubleshooting, you can press the reset button to continue working. If it is not used for a long time, the Freon of the system should be pumped back into the liquid storage cylinder, and the in and out valves of the liquid storage cylinder should be closed.

Check whether the inner wall of the tank is corroded or damaged. Compressor is hot  The cooling capacity decreases  The return steam pipe does not form frost and does not sweat Freon must be added to the above conditions. How can it be memorialized maintenance? Let's learn more about it below. 3. 6.2MPa). The lack of fluorine in the system can be determined according to the following aspects. Direct cooling milk tank has beautiful appearance, compact structure, high degree of automation and small floor space. It not only saves energy, but also can keep the milk at low temperature for a long time

Classification according to the way of impeller discharge

Single-side inlet pump: also called single-suction pump, that is, there is only one water inlet on the impeller; 2. Vertical pump: the pump shaft is in the vertical position. Multi-stage pump: that is, there are two or more impellers on the pump shaft. Single-stage pump: that is, there is only one impeller on the pump shaft. 3. Before starting, you need to fill the pump casing and suction pipe with water, and then drive the motor to make the impeller rotate at high speed.

Classification according to the way of impeller discharge 1. Classification by the number of impellers 1. Suction centrifugal pump (non-self-filling centrifugal pump): the pump shaft is higher than the surface of the suction pool. The water is thrown out of the impeller by centrifugal force, and negative pressure is formed in the center of the impeller. At this time, the total head of the pump is the sum of the heads produced China beer brewhouse by n impellers.  Classification according to the combination of pump casing 1. Guide vane pump: After the water comes out of the impeller, it enters the guide vane set outside it, and then enters the next stage or flows into the outlet pipe.

Volute pump: After the water comes out of the impeller, it directly enters the pump casing with a spiral shape. Vertical joint surface pump: the joint surface is perpendicular to the axis line.  Double-side inlet pump: also called double-suction pump, that is, both sides of the impeller All have an inlet.  Classification according to the impeller suction method 1. Low pressure pump: pressure lower than 100 meters water column; 2. The water in the suction pool enters the impeller under the action of atmospheric pressure.

It is also affected by the high-speed rotating impeller and is thrown out of the impeller into the pressurized water pipeline. Horizontally split pump: that is, there is a joint seam on the horizontal plane passing through the axis line. Centrifugal pumps are divided into many types. Classification by working pressure 1. Classification by installation height 1. Medium pressure pump: pressure between 100 and 650 meters water column; 3. Classification by pump shaft position 1. 2.We know that centrifugal pumps work by using the rotation of the impeller to make the water produce centrifugal movement.

Its flow rate is twice that of a single-suction pump, which can be roughly regarded as two single-suction pump impellers placed back to back together. High pressure pump: pressure higher than 650 meters water column. Let's learn about the types of centrifugal pumps in detail below. 2. 2. Nowadays, centrifugal pumps are also very popular and well-known by people. Horizontal pump: The pump shaft is in a horizontal position. 2. Self-filling centrifugal pump: The pump shaft is lower than the surface of the suction pool, and it can be started automatically without watering when starting