The milk tank equipment should be managed by a dedicated person.. Check the action of the high and low pressure controller, whether the pressure indicating position has changed, and whether the internal components of the control tank are rusted or damaged. The direct cooling milk storage tank adopts fully automatic control, and the electric control box can be installed on the side or near end of the milk tank for easy automatic control. In case of the above-mentioned faults, the circuit will be automatically disconnected, an alarm will be issued, and the compressor will stop working. When operating, pay attention to the operation of the refrigeration system and keep a record of the operation.
The dryer filter should be cleaned every year, and the desiccant should be cleaned , Drying or exchange. The refrigeration system should be checked for leaks with halogen lamps once a month. Check whether the mixer is short of oil and whether the oil seal is intact. The compressor has high-pressure pressure fault protection and motor overload protection (high-pressure protection value is 2. Any machine needs maintenance during use, and the same is true for direct cooling milk tanks. If abnormal conditions are found, the maintenance should be stopped in time. 5. If leaks are found, further comprehensive inspections are required. Check whether the digital display temperature controller is sensitive.0MPa, low-pressure shutdown value is 0. The refrigeration plate of the direct cooling milk tank has high refrigeration efficiency.
When the refrigeration unit is out of use in winter, the water in beer brewhouse Supplies the water condenser coil should be drained to prevent the coil from freezing and cracking. The milk tank equipment is combined with the electrical control box to automatically control the temperature of the refrigeration system. Because the insulation layer is filled with rigid foam material with low thermal conductivity, it is light in weight and excellent in insulation performance. The two refrigeration plates are respectively controlled by two sets of refrigeration compressors, which can work independently or at the same time to ensure that the milk is cooled quickly and uniformly without icing. You must check at this time After troubleshooting, you can press the reset button to continue working. If it is not used for a long time, the Freon of the system should be pumped back into the liquid storage cylinder, and the in and out valves of the liquid storage cylinder should be closed.
Check whether the inner wall of the tank is corroded or damaged. Compressor is hot The cooling capacity decreases The return steam pipe does not form frost and does not sweat Freon must be added to the above conditions. How can it be memorialized maintenance? Let's learn more about it below. 3. 6.2MPa). The lack of fluorine in the system can be determined according to the following aspects. Direct cooling milk tank has beautiful appearance, compact structure, high degree of automation and small floor space. It not only saves energy, but also can keep the milk at low temperature for a long time
Megosztás a facebookon